Electrical Grounding & Lightning Protection : CASE STUDY AND PROBLEM SOLVING
Bali / Batam | 1-2 Oktober 2012 | Rp. 7.850.000 Per Peserta
Bandung / Jakarta / Surabaya | 1-2 Oktober 2012 | Rp. 6.500.000 Per Peserta
Bali / Batam | 8 – 9 Oktober 2012 | Rp. 7.850.000 Per Peserta
Bandung / Jakarta / Surabaya | 8-9 Oktober 2012 | Rp. 6.500.000 Per Peserta
Bali / Batam | 15-16 Oktober 2012 | Rp. 7.850.000 Per Peserta
Bandung / Jakarta / Surabaya | 15-16 Oktober 2012 | Rp. 6.500.000 Per Peserta
Bali / Batam | 22 – 23 Oktober 2012 | Rp. 7.850.000 Per Peserta
Bandung / Jakarta / Surabaya | 22 – 23 Oktober 2012 | Rp. 6.500.000 Per Peserta
Bali / Batam | 29-30 Oktober 2012 | Rp. 7.850.000 Per Peserta
Bandung / Jakarta / Surabaya | 29-30 Oktober 2012 | Rp. 6.500.000 Per Peserta
Bali / Batam | 5 – 6 November 2012 | Rp. 7.850.000 Per Peserta
Bandung / Jakarta / Surabaya | 5 – 6 November 2012 | Rp. 6.500.000 Per Peserta
Bali / Batam | 12-13 November 2012 | Rp. 7.850.000 Per Peserta
Bandung / Jakarta / Surabaya | 12-13 November 2012 | Rp. 6.500.000 Per Peserta
Bali / Batam | 19 – 20 November 2012 | Rp. 7.850.000 Per Peserta
Bandung / Jakarta / Surabaya | 19 – 20 November 2012 | Rp. 6.500.000 Per Peserta
Bali / Batam | 26-27 November 2012 | Rp. 7.850.000 Per Peserta
Bandung / Jakarta / Surabaya | 26-27 November 2012 | Rp. 6.500.000 Per Peserta
Bali / Batam | 3 – 4 Desember 2012 | Rp. 7.850.000 Per Peserta
Bandung / Jakarta / Surabaya | 3 – 4 Desember 2012 | Rp. 6.500.000 Per Peserta
Bali / Batam | 10-11 Desember 2012 | Rp. 7.850.000 Per Peserta
Bandung / Jakarta / Surabaya | 10-11 Desember 2012| Rp. 6.500.000 Per Peserta
Bali / Batam | 17-18 Desember 2012 | Rp. 7.850.000 Per Peserta
Bandung / Jakarta / Surabaya | 17-18 Desember 2012 | Rp. 6.500.000 Per Peserta
Bali / Batam | 26 – 27 Desember 2012 | Rp. 7.850.000 Per Peserta
Bandung / Jakarta / Surabaya | 26 – 27 Desember 2012 | Rp. 6.500.000 Per Peserta
Jadwal Training 2013 Selanjutnya …
Description
The backbone of many electric power systems is the medium voltage distribution system. Typically operating at voltages ranging from 2,400 to 34,500 Volts, voltage stress, corona, surges and protection of equipment all create unique challenges in design, equipment selection, operation and engineering. This 2 day class takes you through the basics of medium voltage power systems including components,equipment, design and operation problems as well as protection of medium voltage systems.
Outline
MEDIUM VOLTAGE SAFETY
- Electrocution at Low vs. Medium Voltage, Arc Flash,
- Qualified Person, Approach Boundaries
TYPES OF MEDIUM VOLTAGE SYSTEMS
- Utility and Industrial One lines, Reliability Requirements,
- Overhead and Underground Systems, Regulated Systems
MEDIUM VOLTAGE CABLE
- Copper vs. Aluminum Design, Voltage Ratings
- Insulation Ratings, 100%, 133%, 173% Insulation Levels,
- Shielding Requirements, Electric Fields, Terminating MV
- Conductors, Orientation of Overhead Lines
MEDIUM VOLTAGE SUBSTATION TRANSFORMERS
- Core and Coil Design, Aluminum and Copper Windings
- Tank Construction, Loss Evaluation, Efficiency, Regulation
SPOT NETWORKS
- Spot Network Design, Network Protectors, Network Protector
- Relay Operation, Directional Protection Requirements
PARTIAL DISCHARGE
- Corona, Surface Tracking, Voltage Stress, Sensing Partial
- Discharge, Component Failure
GROUNDING MEDIUM VOLTAGE SYSTEMS
- Resistance Grounding, Solid Grounding, Ungrounded Delta
- Charging Current, Effect of Ground Faults on Delta Voltage
SURGE PROTECTION
- Lightning and Switching Surges, Classes of Surge Arresters
- MCOV Ratings – (Maximum Continuous Operating Voltage)
- TOV – (Maximum Temporary Over Voltage Capability),
- Protective Characteristics, Surge Arrester Selection, Energy
- Capability, Effect of Grounding on Arrestor Selection,
- Insulation Coordination,
CURRENT TRANSFORMER APPLICATIONS
- Ratings, Selection Process, Accuracy, Saturation, Excitation
- Curves, Burden Calculation, Momentary Ratings
MEDIUM VOLTAGE CIRCUIT BREAKERS
- Vacuum, Air, Oil, SF6 Designs, Symmetrical Interrupting
- Rating, K-Rated Voltage Factor, Close and Latch Capability
RECLOSERS
- Application on Feeder Circuits, Recloser Settings
- Continuous Current and Interrupting Ratings
MEDIUM VOLTAGE FUSES
- Medium Voltage Switches, Load Rating, Close and Latch
- Rating, Short Time Rating, Expulsion vs. Current Limiting
- Fuse Characteristics, E and R Rated Fuses, Fuse Cutouts
MEDIUM VOLTAGE PROTECTION CONCEPTS
- Medium Voltage Protection, Relays, Circuit Breakers, R and
- E rated Fuses, Short Circuit vs. Overcurrent Protection
DISTRIBUTION FEEDER PROTECTION
- Protection with Fuses – 300%, Overcurrent Protection with
- Relays – 600%, Short Circuit Damage Characteristics, Relay
- “Reach” for End of Line Faults
ROTATING MACHINERY PROTECTION
- Requirements, Decrement Curves, Thermal Damage Curves,
- Reactive, Capability Curves, Differential Protection
MEDIUM VOLTAGE MOTOR CONTROLLERS
- Protection Requirements, Motor Management Relays, Circuit
- Breaker Protection, Relaying, Class R Rated Fuses
TRANSFORMER PROTECTION
- ANSI C57 Thru Fault Curves, Impact of Transformer Winding
- Configuration, Overview of Differential Protection, Inrush and
- Harmonic Restraint
Participants
- D3 atau SLTA yang berpengalaman kerja minimal 3 tahun, dan atau setara.
- Teknisi, Operator dan Supervisor didalam bidang management kelistrikan dan atau non teknik.
- Mereka yang dalam tugasnya berhubungan dan atau terkait dengan materi kursus.
Metode
Presentation, discuss, case study.
Waktu Dan Tempat
Hotel All Seasons Legian, Bali / Hotel Nagoya Plaza, Batam
- 3-4 September 2012
- 17-18 September 2012
- 1-2 Oktober 2012
- 8 – 9 Oktober 2012
- 15-16 Oktober 2012
- 22-23 Oktober 2012
- 29-30 Oktober 2012
- 5-6 November 2012
- 12-13 November 2012
- 19-20 November 2012
- 26-27 November 2012
- 3-4 Desember 2012
- 10-11 Desember 2012
- 17-18 Desember 2012
- 26-27 Desember 2012
Hotel Ibis Surabaya/ Hotel Twin Plaza, Jakarta/ Hotel Golden Flower Bandung
- 1-2 Oktober 2012
- 8 – 9 Oktober 2012
- 15-16 Oktober 2012
- 22-23 Oktober 2012
- 29-30 Oktober 2012
- 5-6 November 2012
- 12-13 November 2012
- 19-20 November 2012
- 26-27 November 2012
- 3-4 Desember 2012
- 10-11 Desember 2012
- 17-18 Desember 2012
- 26-27 Desember 2012
Jadwal Training 2013
Electrical Grounding & Lightning Protection : CASE STUDY AND PROBLEM SOLVING
Tempat (Tentative):
Hotel Ibis Surabaya
Hotel Twin Plaza Jakarta
Hotel Golden Flower Bandung
Hotel All Seasons Legian,Bali
Hotel Nagoya Plaza, Batam
Tanggal:
- 02 – 03 Januari 2013
- 07 – 08 Januari 2013
- 14 – 15 Januari 2013
- 21 – 22 Januari 2013
- 28 – 29 Januari 2013
- 04 – 05 Februari 2013
- 11 – 12 Februari 2013
- 18 – 19 Februari 2013
- 25 – 26 Februari 2013
- 04 – 05 Maret 2013
- 13 – 14 Maret 2013
- 18 – 19 Maret 2013
- 25 – 26 Maret 2013
- 01 – 02 April 2013
- 08 – 09 April 2013
- 15 – 16 April 2013
- 22 – 23 April 2013
- 29 – 30 April 2013
- 06 – 07 Mei 2013
- 13 – 14 Mei 2013
- 20 – 21 Mei 2013
- 27 – 28 Mei 2013
- 03 – 04 Juni 2013
- 10 – 11 Juni 2013
- 17 – 18 Juni 2013
- 24 – 25 Juni 2013
- 01 – 02 Juli 2013
- 08 – 09 Juli 2013
- 15 – 16 Juli 2013
- 22 – 23 Juli 2013
- 29 – 30 Juli 2013
- 12 – 13 Agustus 2013
- 19 – 20 Agustus 2013
- 26 – 27 Agustus 2013
- 02 – 03 September 2012
- 09 – 10 September 2013
- 16 – 17 September 2012
- 23 – 24 September 2013
- 30 September – 01 oktober 2013
- 07 – 08 Oktober 2013
- 16 – 17 Oktober 2013
- 21 – 22 Oktober 2013
- 28 – 29 Oktober 2013
- 06 – 07 November 2013
- 11 – 12 November 2013
- 18 – 19 November 2013
- 25 – 26 November 2013
- 02 – 03 Desember 2013
- 09 – 10 Desember 2013
- 16 – 17 Desember 2013
- 23 – 24 Desember 2013
- 30 – 31 Desember 2013
Investasi dan Fasilitas
- Rp.7.850.000 (Non Residential) untuk lokasi di Bali atau Batam
- Rp. 6.500.000 (Non Residential) untuk lokasi di Bandung
- Quota minimum 3 peserta
- Fasilitas : Certificate,Training kits, USB, Lunch, Coffee Break, Souvenir
Tugino, ST.,MT dan Tim
Having knowledge and experience as practician and trainer in Electricity Maintenance.
cforms contact form by delicious:days