ELECTRICAL INSTALLATION IN HAZARDOUS AREA
Bali | 22 – 24 April 2015 | IDR 8.000.000 per participant
Bandung | 22 – 24 April 2015 | IDR 7.000.000 per participant
Yogyakarta | 22 – 24 April 2015 | IDR 6.500.000 per participant
Bali | 28 – 30 April 2015 | IDR 8.000.000 per participant
Bandung | 28 – 30 April 2015 | IDR 7.000.000 per participant
Yogyakarta | 28 – 30 April 2015 | IDR 6.500.000 per participant
Jadwal Training 2015 Selanjutnya …
TRAINING OUTLINES
Explosive Atmosphere, origin and characteristic values
- Evaporation
- Convection, diffusion density ratio
- Flash point and combustion point
- Classification of flammable liquids into danger classes
- Explosive mixture of dust and air
- Exothermic chemical reaction and its characteristic values
- Ignition sources and their characteristic values
- Ignition flame
- Influence of electrical values
- Ex-groups, maximum experimental safe gap
- Ignition by hot surfaces
Regulation and Specifications
- Regulations concerning electrical installations in explosive atmosphere
- Definitions
- Potentially explosive atmosphere, electrical apparatus in acetylene plants
- IEC works
Type of Protection
- General, opening apparatus, terminals, cable and conduct entries
- Oil immersed equipments
- Pressurized appartus
- Flameproof enclosure
Intrinsic safety
- General specific constructional requirements
- Installation requirements for intrinsically safe circuits
- Tests
Planning, installation and operation of electrical systems in potentially explosive atmospheres
- Assessment of possible explosion risk
- Planning electrical installations for use in potentially explosive atmosphere
- Selection of apparatus
- Measuring and control equipment
- Lighting systems
Operation of electrical equipment in potentially explosive atmosphere
- General
- Operations of electrical equipment
- Instruction of persons
- Repair of explosion-protected electrical apparatus
- Repair work not affecting the explosion protection
Switchgear for use in potentially explosive atmospheres
- Terminals
- Protection against dust and wear,
- Types of protection for electrical switchgear
Lamps and Luminaires
- General, incandescent lamps, discharge lamps, high pressure mercury lamps
- Safety luminaires, portable lights, flameproof luminaires
- Pressurized luminaires
INSTRUCTOR
Tugino, ST MT and team
PARTICIPANTS
Managers involved with energy management, Electrical engineers and Technical Staff who have to deal with the aspect of electrical and industrial power system protection, control and operation.
TIME & VENUE
- 22-24 April 2015
- 28-30 April 2015
- 5-7 Mei 2015
- 20-22 Mei 2015
- 27-29 Mei 2015
- 8-10 Juni 2015
- 16-18 Juni 2015
- 24-26 Juni 2015
- 8-10 Juli 2015
- 14-16 Juli 2015
- 27-29 Juli 2015
- 5-7 Agustus 2015
- 18-20 Agustus 2015
- 26-28 Agustus 2015
- 2-4 September 2015
- 9-11 September 2015
- 28-30 September 2015
- 12-14 Oktober 2015
- 20-22 Oktober 2015
- 26-28 Oktober 2015
- 11-13 November 2015
- 16-18 November 2015
- 25-27 November 2015
- 21-23 Desember 2015
- Hotel Horison Ultima-Riss | Yogyakarta
TRAINING FEE
- IDR 6.500.000 per participant (Non-Residential)
- Minimal participants : 2 persons (Yogyakarta)
- Yogyakarta : Ibis Styles Dagen, Ibis Malioboro, Horison Ultima-Riss, Harper Mangkubumi, 101 Hotel, Grand Tjokro, Novotel, Grand Aston, Phoenix Hotel | Kuota Min. Peserta: 2 orang
- Bali : Ibis Styles Kuta, Ibis Dewi Sri, Ibis Bali Kuta, Ibis Circle Kuta, Harris Hotel | IDR. 8.000.000 Per Peserta (Non-Residential) | Kuota Min. Peserta: 5 orang
- Bandung : De Batara, Amaris, Golden Flower Hotel | IDR. 7.000.000 Per Peserta (Non-Residential) | Kuota Min. Peserta: 5 orang
FACILITIES
- Training Modul
- Stationeries
- Certificate
- Backpack
- Exclusive Polo shirt
- Flashdisk containing materials
- Training photo
- 2x coffee break and lunch
- Transportation Service from airport to hotel / training venue (at least for 2 participants from the same company).