DESCRIPTION
This course gives you a fundamental understanding of the installation, operation and troubleshooting of variable speed drives. You will learn the basic setup of parameters, control wiring and safety precautions in installing a VSD. The various drive features such as operating modes, braking types, automatic restart and many others will be discussed in detail. You will learn the four basic requirements for a VSD to function properly with emphasis on typical controller faults, their causes and how they can be repaired.
OBJECTIVES
- Demonstrate a sound understanding of how AC Variable Speed Drives (VSD’s) work
- Install VSDs properly
- Select the right VSD for a given application
- Troubleshoot VSDs competently
- Competently explain how flux-vector control works for drive applications understand squirrel cage induction motors
- Identify the protection and control system requirements for VSD’s
- Interface VSD’s with PLCs
- Understand the causes of motor burnout
- Deal effectively with VSD harmonics and
- EMC/EMI problems
TRAINING OUTLINES
Introduction To Variable Speed Drives
- The Need for Variable Speed Drives
- Fundamental Principles of Speed Control
- Efficiency, Torque, Inertia,
- Horsepower/Power Factor
- Torque-Speed Curves
- How the motor produces Torque
- Types of Variable Speed Drives
3-Phase Ac Induction Motors
- Basic Construction and Physical Configuration
- Principles of Operation and Performance
- Equivalent Circuit and Fundamental Equations
- Starting, Acceleration, Running and Stopping
- Power, Torque and Thermal Rating
Power Electronic Converters
- Definitions and Basic Principles
- Power Diodes and Thyristors
- Principles of Communication
- Power Electronic Rectifiers
- Power Electronic Inverters
- Gate Commutated Converters
- Gate Controlled Devices – GTO, FCT, GTR, FET, IGBT
Electromagnetic Compatibility (EMC)
- Sources of Electromagnetic Interference
- Harmonics on the Power Supply side of AC Converters
- The Effect of Harmonic Distortion on other connected Equipment
- Methods of reducing the effect of Supply side Harmonics
- Electric Motor Protection
- Thermal Overload Protection – Current Sensing
- Thermal Overload Protection – Direct Temperature Sensing
Protection Of Motors And Converters
- AC Frequency Converter Protection Fault Diagnostics
- Electric Motor Protection
- Thermal Overload Protection – Current Sensors
- Thermal Overload Protection – Direct Temperature
Control System For AC Variable Speed Drives
- The Overall Control System
- Power Supply to the Control System
- DC Bus Charging System
- VSD Control Loops (Open-Loop, Closed- Loop)
- Vector control and its applications Current Feedback in AC Variable Speed Drives\
- Speed Feedback from the Motor
The Selection Of AC Converters For Variable Speed Drive Applications
- The Basic Selection Procedure
- Loadability of Converter Fed induction Motors
- Operation in the Constant Power Region\
- The Nature of the Machine Load
- Starting and Stopping VSDs (Motor Braking)
The Selection Of AC Converters (Continued)
- How to Calculate Acceleration Torques and Times
- How to Select the correct Motor and
- Converter for Pump and Fan Loads
- How to Select the correct Motor and
- Converter for Constant Torque Loads, such as conveyors
- Summary of the Selection Procedure
Installation And Fault Finding Techniques
- General Installation and Environmental Requirements
- Power Supply Connections and Earthing
- Where to install the Contactors in the Power Where to install the Contactors in the Power Circuit
- Installing AC Converters into Metal Enclosures
INSTRUCTOR
Miftahul Huda, ST, M. Eng. and team
TIME & VENUE
- 21-23 April 2015
- 6-8 Mei 2015
- 11-13 Mei 2015
- 26-28 Mei 2015
- 1-3 Juni 2015
- 16-18 Juni 2015
- 23-25 Juni 2015
- 1-3 Juli 2015
- 14-16 Juli 2015
- 28-30 Juli 2015
- 4-6 Agustus 2015
- 11-13 Agustus 2015
- 25-27 Agustus 2015
- 1-3 September 2015
- 15-17 September 2015
- 21-23 September 2015
- 6-8 Oktober 2015
- 12-14 Oktober 2015
- 20-22 Oktober 2015
- 3-5 November 2015
- 17-19 November 2015
- 24-26 November 2015
- 1-3 Desember 2015
- 8-10 Desember 2015
- 15-17 Desember 2015
- 21-23 Desember 2015
- Hotel Novotel | Yogyakarta
TRAINING FEE
- IDR 6.500.000 per participant (Non-Residential)
- Minimal participants : 2 persons (Yogyakarta)
- Yogyakarta : Ibis Styles Dagen, Ibis Malioboro, Horison Ultima-Riss, Harper Mangkubumi, 101 Hotel, Grand Tjokro, Novotel, Grand Aston, Phoenix Hotel | Kuota Min. Peserta: 2 orang
- Bali : Ibis Styles Kuta, Ibis Dewi Sri, Ibis Bali Kuta, Ibis Circle Kuta, Harris Hotel | IDR. 8.000.000 Per Peserta (Non-Residential) | Kuota Min. Peserta: 5 orang
- Bandung : De Batara, Amaris, Golden Flower Hotel | IDR. 7.000.000 Per Peserta (Non-Residential) | Kuota Min. Peserta: 5 orang
FACILITIES
- Training Modul
- Stationeries
- Certificate
- Backpack
- Exclusive Polo shirt
- Flashdisk containing materials
- Training photo
- 2x coffee break and lunch
- Transportation Service from airport to hotel / training venue (at least for 2 participants from the same company).