Medium Voltage Circuit Breakers & Contactors

Medium Voltage Circuit Breakers & Contactors

The Grand Seriti  Hotel, Bandung | 21 – 23 Juni 2013 | IDR 5.499.000,-/participant
The Grand Seriti  Hotel, Bandung | 11 – 13 September 2013 | IDR 5.499.000,-/participant
The Grand Seriti  Hotel, Bandung | 18 – 20 Desember 2013 | IDR 5.499.000,-/participant


Abtract

In an electric power system, switchgear is the combination of electrical disconnect switches, fuses or circuit breakers used to control, protect and isolate electrical equipment. Switchgear is used both to de-energize equipment to allow work to be done and to clear faults downstream. This type of equipment is important because it is directly linked to the reliability of the electricity supply.

Typically switchgear in substations is located on both the high voltage and the low voltage side of large power transformers. The switchgear on the low voltage side of the transformers may be located in a building, with medium-voltage circuit breakers for distribution circuits, along with metering, control, and protection equipment. For industrial applications, a transformer and switchgear line-up may be combined in one housing, called a unitized substation or USS.

This course is designed for technicians and engineers who are responsible for maintenance of medium voltage air / vacuum circuit breakers and contactors (Magne-Blast, Power/VAC and Limit amp equipment). Two-thirds of the class is dedicated to hands-on laboratory work.

Course Content

 Magne-Blast circuit breakers

  • Drawings
  • Switchgear protective relays
  • Ml-13 operating mechanism
  • Adjustments and maintenance

Power/VAC circuit breakers

  • Drawings
  • Ml-17 operating mechanism
  • Ml-18 operating mechanism
  • Adjustments and maintenance

Limit amp motor controllers

  • Drawings
  • Limit amp air-break contactors
  • Limit amp vacuum contactors
  • Adjustments and maintenance

Who Should Attend

Engineer, maintenance, operator, supervisor

Methode :

  • Presentation
  • Discussion
  • Case Study
  • Evaluation
  • Practise

Instructors

  • Ir. Teguh Santosa
  • Tito Yuwono, ST, M.Eng.

Experts and practitioners who are active as instructors in various training and seminars related to the field of Electrical Engineering

TEMPAT DAN WAKTU

Waktu           : 08.30-16.30 WIB
Tempat         :  The Grand Seriti  Hotel bandung
Tanggal        :

  • 20 – 22 Maret 2013  (Bacth I)
  • 21 – 23 Juni 2013 (Bacth II)
  • 11 – 13 September 2013 (Bacth III)
  • 18 – 20 Desember 2013 (Batch IV)

INVESTASI

  • IDR 5.499.000,-/participant non residensial.
  • For send 3 participant discount 10 %.

 FASILITAS

  • Meeting Room Hotel ****
  • Training KIT
  • Souvenir
  • Sertifikat
  • 2 X Coffe Break + Lunch
Formulir Permintaaan Informasi Lanjutan / Pra-Pendaftaran Public Training
  1. INFORMATION OPTIONS
  2. (required)
  3. (required)
  4. PERSONAL DATA
  5. (required)
  6. (required)
  7. (required)
  8. (valid email required)
  9. (required)
  10. (required)
  11. PRE REGISTRATION DATA (Tidak Mengikat)
  12. (required)
  13. MESSAGE FOR TRAINING PROVIDER
  14. Captcha
 

cforms contact form by delicious:days